▪Compact design, single-axis digital display, with the new absolute warning system (AWS) equipped.

▪AWS constantly guarantee the accuracy of the displayed items and informs the operator in case of malfunction.

▪The user can continue editing or intervene on the basis of the error message is displayed and restore the proper functioning of the system.

▪Suitable for various machine tools, such as cutting, measuring, polishing, calendering, or grinding.

▪Can be used as for working with wood, metal, marble, rubber, textiles and automation in various fields.

▪Absolute (SSI protocol) or incremental encoder inputs. Absolute signals RS422: Clock In, Clock, Data +, Data-.

▪Up to 8 digit display, including comma and minus sign.

▪Device diagnostics.

▪Internal rewritable memory.

▪Resolutions up to 0.5 microns.

▪Correction factor, angle measurement, programmable relay outputs and many other functions are available.

▪Serial output RS-232, for the transfer of positions.

▪Possibility with mounting plate.

FUNCTIONS

  • SELF-TESTING
  • MIDPOINT CALCULATION
  • LOAD POSITION PRESET
  • SETTING SSI PARAMETERS
  • POSITION RESET/PRESET
  • MEMORY CLEARING
  • ABSOLUTE/INCREMENTAL COUNTING
  • LINEAR CORRECTION
  • VARIABLE RESOLUTION
  • ANGULAR READING
  • RADIUS/DIAMETER CONVERSION
  • SEXAGESIMAL DEGREES READING
  • MM/INCH CONVERSION
  • RELAY OUTPUTS ACTIVATION (opt.)
  • SCALE ZERO REFERENCE (REF)
  • SETTING TIMED RELAY OUTPUTS (opt.)
  • DISABLING SCALE ZERO REFERENCE
  • SETTING INTERVENTION POSITIONS (opt.)
  • COUNTING MODE (x1, x2, x4)
  • RS-232 SERIAL OUTPUT (opt.)
  • INVERSION OF COUNTING DIRECTION
  • ENABLING THE AUTOMATIC TRANSMISSION OF POSITIONS


TypeDisplayIncremental encoder input signalsAbsolute (SSI) encoder input signalsPower supplyMemoryAvailable resolutionsOptions Datenblatt
VI5188 high-efficiency digits h = 13 mm2 square waves with phase displacement of 90° ± 5° and zero ref.
5 Vdc or 12 Vdc
230 Vac ± 10% - 50/60 Hz 40 mA
110 Vac ± 10% - 60 Hz 80 mA
24 Vac ± 10% - 50/60 Hz 350 mA
permanent for configuration
and “user” settings
(last data operating memory)
200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 - 0.5 μm
1° - 0.5° - 0.2° - 0.1° - 0.05° - 0.02° - 0.01° - 0.005° - 0.002° - 0.001°
VI518_2download PDF
VI5188 high-efficiency digits h = 13 mm2 square waves with phase displacement of 90° ± 5° and zero ref.
5 Vdc or 12 Vdc
RS-422: Clock+, Clock-, Data+, Data-230 Vac ± 10% - 50/60 Hz 40 mA
110 Vac ± 10% - 60 Hz 80 mA
24 Vac ± 10% - 50/60 Hz 350 mA
permanent for configuration
and “user” settings
(last data operating memory)
200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 - 0.5 μm
1° - 0.5° - 0.2° - 0.1° - 0.05° - 0.02° - 0.01° - 0.005° - 0.002° - 0.001°
serial output RS-232
relay outputs
static relays AC - static relays DC
absolute (SSI) encoder input
VI518_1download PDF